Do position the device
- along opening edge of the door/window opposite the hinges
- with Magnet on opening part of door/window
- with Detector on fixed frame
- with the mark on Magnet & Detector aligned
- so that the gap between Magent & Detector is less than 10mm when the door/window is closed
- within radio range of the Control Panel (or Siren)
Don't position the device
- directly onto, behind or very close to metalwork
|
|